;{CR10X-TD} *Table 1 Program 01: 60.0000 Execution Interval (seconds) 1: Signature (P19) 1: 1 Loc [ ProgSig ] 2: Batt Voltage (P10) 1: 2 Loc [ Battery ] 3: Internal Temperature (P17) 1: 3 Loc [ PnlTemp ] 4: SDI-12 Recorder (P105) 1: 0 SDI-12 Address 2: 0 Start Measurement (aM!) 3: 5 Port 4: 11 Loc [ PTstage ] 5: 1 Multiplier 6: 0 Offset 5: Z=X*F (P37) 1: 11 X Loc [ PTstage ] 2: 70.307 F 3: 11 Z Loc [ PTstage ] 6: AC Half Bridge (P5) 1: 1 Reps 2: 25 2500 mV 60 Hz Rejection Range 3: 6 SE Channel 4: 1 Excite all reps w/Exchan 1 5: 2500 mV Excitation 6: 23 Loc [ x ] 7: 1 Multiplier 8: 0 Offset 7: Z=1/X (P42) 1: 23 X Loc [ x ] 2: 23 Z Loc [ x ] 8: Z=X+F (P34) 1: 23 X Loc [ x ] 2: -1 F 3: 23 Z Loc [ x ] 9: Z=X*F (P37) 1: 23 X Loc [ x ] 2: 24900 F 3: 4 Z Loc [ thermR ] 10: Z=LN(X) (P40) 1: 4 X Loc [ thermR ] 2: 24 Z Loc [ y ] 11: Z=X*F (P37) 1: 24 X Loc [ y ] 2: .00100 F 3: 24 Z Loc [ y ] 12: Polynomial (P55) 1: 1 Reps 2: 24 X Loc [ y ] 3: 24 F(X) Loc [ y ] 4: .00113 C0 5: .23411 C1 6: 0 C2 7: 87.755 C3 8: 0 C4 9: 0 C5 13: Z=1/X (P42) 1: 24 X Loc [ y ] 2: 5 Z Loc [ ATK ] 14: Z=X+F (P34) 1: 5 X Loc [ ATK ] 2: -273.15 F 3: 6 Z Loc [ AT ] 15: SDI-12 Recorder (P105) 1: 0 SDI-12 Address 2: 0 Start Measurement (aM!) 3: 3 Port 4: 8 Loc [ SR50raw ] 5: -100 Multiplier 6: 0 Offset 16: Z=F x 10^n (P30) 1: 273.15 F 2: 0 n, Exponent of 10 3: 25 Z Loc [ z ] 17: Z=X/Y (P38) 1: 5 X Loc [ ATK ] 2: 25 Y Loc [ z ] 3: 25 Z Loc [ z ] 18: Z=SQRT(X) (P39) 1: 25 X Loc [ z ] 2: 25 Z Loc [ z ] 19: Z=X*Y (P36) 1: 8 X Loc [ SR50raw ] 2: 25 Y Loc [ z ] 3: 9 Z Loc [ SR50down ] 20: Z=X+F (P34) 1: 9 X Loc [ SR50down ] 2: 500 F 3: 10 Z Loc [ SR50stage ] 21: SDI-12 Recorder (P105) 1: 0 SDI-12 Address 2: 0 Start Measurement (aM!) 3: 1 Port 4: 27 Loc [ SR50raw2 ] 5: -100 Multiplier 6: 0 Offset 22: Z=F x 10^n (P30) 1: 273.15 F 2: 0 n, Exponent of 10 3: 25 Z Loc [ z ] 23: Z=X/Y (P38) 1: 5 X Loc [ ATK ] 2: 25 Y Loc [ z ] 3: 25 Z Loc [ z ] 24: Z=SQRT(X) (P39) 1: 25 X Loc [ z ] 2: 25 Z Loc [ z ] 25: Z=X*Y (P36) 1: 27 X Loc [ SR50raw2 ] 2: 25 Y Loc [ z ] 3: 30 Z Loc [ SR50down2 ] 26: Z=X+F (P34) 1: 30 X Loc [ SR50down2 ] 2: 373 F 3: 31 Z Loc [ SR50stage2 ] 27: If time is (P92) 1: 3540 Seconds into a 2: 3600 Second interval 3: 44 Set Port 4 High 28: If time is (P92) 1: 0 Seconds into a 2: 3600 Second interval 3: 30 Then Do 29: Volt (SE) (P1) 1: 1 Reps 2: 25 2500 mV 60 Hz Rejection Range 3: 2 SE Channel 4: 13 Loc [ PBmBar ] 5: .18400 Multiplier 6: 600 Offset 30: Do (P86) 1: 54 Set Port 4 Low 31: End (P95) 32: Data Table (P84)^25626 1: 0 Seconds into Interval 2: 900 Seconds Interval 3: 0 (0 = auto allocate, -x = redirect to inloc x) 4: STAGE Table Name 33: Sample (P70)^13726 1: 1 Reps 2: 1 Loc [ ProgSig ] 34: Average (P71)^15152 1: 1 Reps 2: 11 Loc [ PTstage ] 35: Average (P71)^13680 1: 1 Reps 2: 12 Loc [ PTtemp ] 36: Average (P71)^10913 1: 1 Reps 2: 10 Loc [ SR50stage ] 37: Average (P71)^4222 1: 1 Reps 2: 6 Loc [ AT ] 38: Sample (P70)^1058 1: 1 Reps 2: 13 Loc [ PBmBar ] 39: Average (P71)^2013 1: 1 Reps 2: 31 Loc [ SR50stage2 ] 40: Data Table (P84)^19416 1: 0 Seconds into Interval 2: 900 Seconds Interval 3: 0 (0 = auto allocate, -x = redirect to inloc x) 4: DIAG Table Name 41: Sample (P70)^31615 1: 1 Reps 2: 1 Loc [ ProgSig ] 42: Sample (P70)^23267 1: 1 Reps 2: 2 Loc [ Battery ] 43: Average (P71)^8118 1: 1 Reps 2: 3 Loc [ PnlTemp ] 44: Average (P71)^6809 1: 1 Reps 2: 4 Loc [ thermR ] 45: Sample (P70)^22507 1: 1 Reps 2: 8 Loc [ SR50raw ] 46: Sample (P70)^10800 1: 1 Reps 2: 9 Loc [ SR50down ] 47: Sample (P70)^30957 1: 1 Reps 2: 27 Loc [ SR50raw2 ] 48: Sample (P70)^3186 1: 1 Reps 2: 30 Loc [ SR50down2 ] *Table 2 Program 01: 60.0000 Execution Interval (seconds) 1: Set Port(s) (P20) 1: 9999 C8..C5 = nc/nc/nc/nc 2: 9997 C4..C1 = nc/nc/nc/output 2: If time is (P92) 1: 0 Seconds into a 2: 3600 Second interval 3: 30 Then Do 3: If (X<=>F) (P89) 1: 2 X Loc [ Battery ] 2: 4 < 3: 12.6 F 4: 21 Set Flag 1 Low 4: If (X<=>F) (P89) 1: 2 X Loc [ Battery ] 2: 3 >= 3: 12.61 F 4: 48 Set Port 8 High 5: End (P95) 6: If time is (P92) 1: 43200 Seconds into a 2: 86400 Second interval 3: 48 Set Port 8 High 7: If Flag/Port (P91) 1: 21 Do if Flag 1 is Low 2: 30 Then Do 8: If time is (P92) 1: 600 Seconds into a 2: 3600 Second interval 3: 58 Set Port 8 Low 9: End (P95) *Table 3 Subroutines End Program -Input Locations- 1 ProgSig 1 2 1 2 Battery 1 3 1 3 PnlTemp 1 1 1 4 thermR 1 2 1 5 ATK 1 3 1 6 AT 1 1 1 7 ______________ 0 0 0 8 SR50raw 1 2 1 9 SR50down 1 2 1 10 SR50stage 1 1 1 11 PTstage 1 2 2 12 PTtemp 1 1 0 13 PBmBar 1 1 1 14 ______________ 0 0 0 15 ______________ 0 0 0 16 ______________ 0 0 0 17 ______________ 0 0 0 18 ______________ 0 0 0 19 ______________ 0 0 0 20 kelvin0C 0 0 0 21 Tratio 0 0 0 22 sqrtTratio 0 0 0 23 x 1 3 3 24 y 1 3 3 25 z 1 6 6 26 Traztio 0 0 0 27 SR50raw2 1 2 1 28 2 1 0 0 29 SR50 1 0 0 30 SR50down2 1 2 1 31 SR50stage2 1 1 1 -Program Security- 0 0 0 -Mode 4- -CR10X ID- 0 -CR10X Power Up- 0 -CR10X RS-232 Setting- -1 -PakBus- 1 5 0 0 0 1 0 0 0 0 1 1 0 DR=0 0 0 0 0 .endAddrSwath .endAddrSwath .endAddrSwath .endAddrSwath -DLD File Labels- -1 -Final Storage Labels- 0,TMSTAMP,25626 0,RECNBR 1,ProgSig~1,13726 2,PTstage_AVG~11,15152 3,PTtemp_AVG~12,13680 4,SR50stage_AVG~10,10913 5,AT_AVG~6,4222 6,PBmBar~13,1058 7,TMSTAMP,19416 7,RECNBR 8,ProgSig~1,31615 9,Battery~2,23267 10,PnlTemp_AVG~3,8118 11,thermR_AVG~4,6809 12,SR50raw~8,22507 13,SR50down~9,10800 14,SR50stage2_AVG~31,2013 15,SR50raw2~27,30957 16,SR50down2~30,3186