'CR200/CR200X Series 'Created by Short Cut (3.2) 'Declare Variables and Units Dim MinIntoDay Public BattV Public CS450(2) Alias CS450(1)=Stage Alias CS450(2)=Temp Units BattV=Volts Units Stage=cm Units Temp=deg C 'Define Data Tables DataTable(Hydro,True,-1) DataInterval(0,15,Min) Sample(1,BattV) Sample(1,Stage) Average(1,Stage,False) Sample(1,Temp) EndTable 'Main Program BeginProg 'Main Scan Scan(60,Sec) 'Default CR200 Series Datalogger Battery Voltage measurement 'BattV' Battery(BattV) SWBatt(True) 'CS450/CS451/CS455/CS456 Pressure Transducer measurements 'Stage' and 'Temp' SDI12Recorder(Stage,"0M1!",1,0) Stage=Stage*70.307 'Radio Timed Control 'Get minutes into current day MinIntoDay=Public.TimeStamp(4,1)/60 'Turn ON SW12 for 10 minutes every 60 minutes If (MinIntoDay MOD 60 < 5) Then SetStatus(Rf_ForceOn,1) Else SetStatus(Rf_ForceOn,0) EndIf 'Call Data Tables and Store Data CallTable Hydro NextScan EndProg