;{CR10X-TD} *Table 1 Program 01: 60.0000 Execution Interval (seconds) 1: Batt Voltage (P10) 1: 1 Loc [ BattV ] 2: If time is (P92) 1: 0 Seconds into a 2: 86400 Second interval 3: 30 Then Do 3: Signature (P19) 1: 2 Loc [ ProgSig ] 4: End (P95) 5: If Flag/Port (P91) 1: 21 Do if Flag 1 is Low 2: 30 Then Do 6: If (X<=>F) (P89) 1: 1 X Loc [ BattV ] 2: 3 >= 3: 12.600 F 4: 30 Then Do 7: Do (P86) 1: 46 Set Port 6 High 8: Else (P94) 9: If (X<=>F) (P89) 1: 1 X Loc [ BattV ] 2: 4 < 3: 12.200 F 4: 56 Set Port 6 Low 10: End (P95) 11: Else (P94) 12: Do (P86) 1: 56 Set Port 6 Low 13: End (P95) 14: If time is (P92) 1: 0 Seconds into a 2: 3600 Second interval 3: 30 Then Do 15: Do (P86) 1: 41 Set Port 1 High 16: Excite-Delay (SE) (P4) 1: 1 Reps 2: 0 Auto Slow Range 3: 1 SE Channel 4: 1 Excite all reps w/Exchan 1 5: 100 Delay (0.01 sec units) 6: 0 mV Excitation 7: 3 Loc [ ______________ ] 8: 1 Multiplier 9: 0 Offset 17: Do (P86) 1: 51 Set Port 1 Low 18: End (P95) 19: Data Table (P84)^31485 1: 0 Seconds into Interval 2: 3600 Seconds Interval 3: 0 (0 = auto allocate, -x = redirect to inloc x) 4: HrlyDiag Table Name 20: Sample (P70)^25549 1: 1 Reps 2: 1 Loc [ BattV ] 21: Sample (P70)^9359 1: 1 Reps 2: 2 Loc [ ProgSig ] *Table 2 Program 01: 0.0000 Execution Interval (seconds) *Table 3 Subroutines End Program -Input Locations- 1 BattV 1 3 1 2 ProgSig 1 1 1 3 ______________ 1 0 1 4 ______________ 0 0 0 5 ______________ 0 0 0 6 ______________ 0 0 0 7 ______________ 0 0 0 8 ______________ 0 0 0 9 ______________ 0 0 0 10 ______________ 0 0 0 11 ______________ 0 0 0 12 ______________ 0 0 0 13 ______________ 0 0 0 14 ______________ 0 0 0 15 ______________ 0 0 0 16 ______________ 0 0 0 17 ______________ 0 0 0 18 ______________ 0 0 0 19 ______________ 0 0 0 20 ______________ 0 0 0 21 ______________ 0 0 0 22 ______________ 0 0 0 23 ______________ 0 0 0 24 ______________ 0 0 0 25 ______________ 0 0 0 26 ______________ 0 0 0 27 ______________ 0 0 0 28 ______________ 0 0 0 -Program Security- 0 0 0 -Mode 4- -CR10X ID- 0 -CR10X Power Up- 0 -CR10X RS-232 Setting- -1 -PakBus- 1 142 0 0 0 1 0 0 0 0 1 1 16 DR=0 0 0 0 0 .endAddrSwath .endAddrSwath .endAddrSwath .endAddrSwath -DLD File Labels- -1 -Final Storage Labels- 0,TMSTAMP,31485 0,RECNBR 1,BattV~1,25549 2,ProgSig~2,9359