;{CR10X-TD} *Table 1 Program 01: 60.0000 Execution Interval (seconds) 1: Batt Voltage (P10) 1: 1 Loc [ BattV ] 2: If time is (P92) 1: 0 Seconds into a 2: 86400 Second interval 3: 30 Then Do 3: Signature (P19) 1: 2 Loc [ ProgSig ] 4: End (P95) 5: SDI-12 Recorder (P105) 1: 0 SDI-12 Address 2: 1 Start Measurement (aM1!) 3: 8 Port 4: 3 Loc [ Stage1 ] 5: 2.3067 Multiplier 6: 59.28 Offset 6: SDI-12 Recorder (P105) 1: 0 SDI-12 Address 2: 5 Start Measurement (aM5!) 3: 8 Port 4: 4 Loc [ WT1 ] 5: 1 Multiplier 6: 0 Offset 7: SDI-12 Recorder (P105) 1: 1 SDI-12 Address 2: 1 Start Measurement (aM1!) 3: 8 Port 4: 5 Loc [ Stage2 ] 5: 2.3067 Multiplier 6: 61.30 Offset 8: SDI-12 Recorder (P105) 1: 1 SDI-12 Address 2: 5 Start Measurement (aM5!) 3: 8 Port 4: 6 Loc [ WT2 ] 5: 1.0 Multiplier 6: 0.0 Offset 9: Data Table (P84)^17870 1: 0 Seconds into Interval 2: 900 Seconds Interval 3: 0 (0 = auto allocate, -x = redirect to inloc x) 4: WaterLevels Table Name 10: Minimum (P74)^12340 1: 1 Reps 2: 0 Value Only 3: 1 Loc [ BattV ] 11: Sample (P70)^5428 1: 1 Reps 2: 3 Loc [ Stage1 ] 12: Sample (P70)^18082 1: 1 Reps 2: 4 Loc [ WT1 ] 13: Sample (P70)^10496 1: 1 Reps 2: 5 Loc [ Stage2 ] 14: Sample (P70)^25112 1: 1 Reps 2: 6 Loc [ WT2 ] 15: Average (P71)^11163 1: 1 Reps 2: 3 Loc [ Stage1 ] 16: Average (P71)^26681 1: 1 Reps 2: 4 Loc [ WT1 ] 17: Average (P71)^27974 1: 1 Reps 2: 5 Loc [ Stage2 ] 18: Average (P71)^31453 1: 1 Reps 2: 6 Loc [ WT2 ] *Table 2 Program 01: 0.0000 Execution Interval (seconds) *Table 3 Subroutines End Program -Input Locations- 1 BattV 1 1 1 2 ProgSig 1 0 1 3 Stage1 1 2 1 4 WT1 1 2 1 5 Stage2 1 2 1 6 WT2 1 2 1 7 ______________ 0 0 0 8 ______________ 0 0 0 9 ______________ 0 0 0 10 ______________ 0 0 0 11 ______________ 0 0 0 12 ______________ 0 0 0 13 ______________ 0 0 0 14 ______________ 0 0 0 15 ______________ 0 0 0 16 ______________ 0 0 0 17 ______________ 0 0 0 18 ______________ 0 0 0 19 ______________ 0 0 0 20 ______________ 0 0 0 21 ______________ 0 0 0 22 ______________ 0 0 0 23 ______________ 0 0 0 24 ______________ 0 0 0 25 ______________ 0 0 0 26 ______________ 0 0 0 27 ______________ 0 0 0 28 ______________ 0 0 0 -Program Security- 0 0 0 -Mode 4- -CR10X ID- 0 -CR10X Power Up- 0 -CR10X RS-232 Setting- -1 -PakBus- 1 1 0 0 0 1 0 0 0 0 1 1 0 DR=0 0 0 0 0 .endAddrSwath .endAddrSwath .endAddrSwath .endAddrSwath -DLD File Labels- -1 -Final Storage Labels- 0,TMSTAMP,17870 0,RECNBR 1,BattV_MIN~1,12340 2,Stage1~3,5428 3,WT1~4,18082 4,Stage2~5,10496 5,WT2~6,25112 6,Stage1_AVG~3,11163 7,WT1_AVG~4,26681 8,Stage2_AVG~5,27974 9,WT2_AVG~6,31453